- Path: dlmlap.supra.com!dan
- From: dan@supra.com (Dan Moore)
- Newsgroups: comp.dcom.modems
- Subject: Re: Supra 288 Retrains and ARA
- Date: Mon, 5 Feb 1996 15:07:19 GMT
- Organization: Supra Corporation
- Message-ID: <dan.844.31161D27@supra.com>
- References: <Leigh-0302961123470001@merlin.alexandria.com>
- NNTP-Posting-Host: dlmlap.supra.com
- X-Newsreader: Trumpet for Windows [Version 1.0 Rev B.7]
-
- In article <Leigh-0302961123470001@merlin.alexandria.com> Leigh@Alexandria.com (Leigh Daniels) writes:
- >I am using the Supra 288/V.34 ARA CCL and when I try to connect to it with
- >a Hayes Optima 288 V.34 modem, the Supra immediately retrains (RT) before
- >ARA can negotiate the connection and so the ARA client using the Hayes
- >times out and disconnects.
-
- Try setting S191 to a higher value, 130 or 132. Higher values
- in S191 cause lower data rates to be negotiated during the initial connection,
- a lower data rate will decrease the need for either modem to initate a retrain
- or rate renegotiation immediately after connection.
-
-
- --
- Dan Moore
- Supra
-
-