home *** CD-ROM | disk | FTP | other *** search
/ NetNews Offline 2 / NetNews Offline Volume 2.iso / news / comp / dcom / modems-part1 / 4074 < prev    next >
Encoding:
Internet Message Format  |  1996-08-05  |  1.0 KB

  1. Path: dlmlap.supra.com!dan
  2. From: dan@supra.com (Dan Moore)
  3. Newsgroups: comp.dcom.modems
  4. Subject: Re: Supra 288 Retrains and ARA
  5. Date: Mon, 5 Feb 1996 15:07:19 GMT
  6. Organization: Supra Corporation
  7. Message-ID: <dan.844.31161D27@supra.com>
  8. References: <Leigh-0302961123470001@merlin.alexandria.com>
  9. NNTP-Posting-Host: dlmlap.supra.com
  10. X-Newsreader: Trumpet for Windows [Version 1.0 Rev B.7]
  11.  
  12. In article <Leigh-0302961123470001@merlin.alexandria.com> Leigh@Alexandria.com (Leigh Daniels) writes:
  13. >I am using the Supra 288/V.34 ARA CCL and when I try to connect to it with
  14. >a Hayes Optima 288 V.34 modem, the Supra immediately retrains (RT) before
  15. >ARA can negotiate the connection and so the ARA client using the Hayes
  16. >times out and disconnects.
  17.  
  18.         Try setting S191 to a higher value, 130 or 132.  Higher values 
  19. in S191 cause lower data rates to be negotiated during the initial connection, 
  20. a lower data rate will decrease the need for either modem to initate a retrain 
  21. or rate renegotiation immediately after connection.
  22.  
  23.  
  24. --
  25. Dan Moore
  26. Supra
  27.  
  28.